2026-07-31

Inbound traffic lost to a group of addresses in AmsterdamA virtual switch restart cleared the flow table fourteen hours earlier without causing an immediate fault. A later routine operation reapplied a partial rule set, interrupting inbound delivery. Flow state is now restored automatically on service start and reconciled every five minutes, with an alert on drift.

Resolved
2026-07-28

One IPv4 prefix unreachable for approximately 30 hoursStale routing registry objects left by a previous address lessor took effect when a transit provider rebuilt its prefix filters. Outbound traffic was unaffected; inbound was not delivered. The objects were removed and filters rebuilt. Registry and RPKI records are now checked daily.

Resolved
2026-04-22

Portal account-identifier confusionA mapping error meant a small number of accounts could briefly see another customer’s services within a session. Patched the same day and reported to the ICO within the statutory window. A regression test is pinned in CI.